Get complete information related to latest Air Grill Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Grill Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Grill Tenders.
Tender For supply of supply and installation of industrial evaporative air cooler , fixing of 22 gauge gi ducting outside dorm , fixing of 24 gauge gi ducting inside dorm , aluminium powder coated supply airgrill for ducting , canvass connection for ducting , covering of ducting with crosslink insulation 9mm with foil , fixing of iron chain link grill for air cooler outside dorms , civil work per dorms
Tender For repair to o.h. water tank, replacement of rusted g.i. water supply pipe, window m.s. grill and drain pipe of staff quarter building no, 10 and 11 juhu adarsh at new d.n. nagar, andheri (w).
Tender For supply, installation, testing and commissioning of air washer unit consists the following : (i) air cooling machine of capacity 51,000 cmh with 2 nos. centrifugal fans (1 no. working & 1 no. stand by), 2 nos. 15 kw electric motors (1 working one standby), v-belt drive for both the fans, celdek pads, 4 bend pvc eliminators, water pump 0.75 kw (1w+1s), water distribution system with pumps, piping?s, valves etc., air intake filters, g.i. air intake louvers,fan outlet electrically operated actuator dampers and complete in all respect as per spec. (ii) supply with erection of of g.i. ducting- supply air-(a) 0.8 mm ( 22 swg )-160 sq. metre (b) 0.6 mm ( 24 swg )-175 sq. metre (iii) supply, erection and commissioning of supply airgrill with vcd of size : 450 x 250 mm-21 nos (iv) supply, installation and commissioning of volume control dampers-2 sq.metre. (v)supply and erection of structural m s support for ducts -500 kg. (vi) supply and erection of gravity air louver size: 300 x 300 mm for exhaust system-21 nos. (vii)supply, erection and commissioning of starter panel drivers -01 set [ warranty period: 36 months after the date of delivery ]
Tender For corrigendum : supply of supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply airgrills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray
Tender For supply of 3 tr single circuit 1 or 3 phase , 1.5tr single circuit 1 or 3 phase , itc of 1.5 or 3.0 tr dac unit , 40 x 40 x 5 mm ms angle iron , 40 x 5 mm ms flat strip , cu ref pipe 6.4 mm dia with insulation , cu ref pipe 9.5 mm dia with insulation , cu ref pipe 12.7 mm dia with insulation , cu ref pipe 15.87 mm dia with insulation , upvc pipe 40mm dia , upvc pipe 25 mm dia , 5c x 4 sqmm pvc cu cable , 3c x 1.5 sqmm pvc cu cable , 4c x 6 sqmm pvc cu cable , dp 25 or 32a 230v c mcb in encl , fp 25 or 32a 415v c mcb in encl , gss sheet ducting 0.63mm , gss sheet ducting 0.80mm , supply airgrills , 100x50x1.6 mm thick cable tray , 150x50x1.6 mm thick cable tray
Tender For supply of set of airgrill for ac power car of bangladesh railways(blwjpclr)., as per drawing: mplgrillbjpclr version 0, packing instruction: brown papper wrapping for individual item collectively packed in wooden boxes [ warranty period: 30 months after the date of delivery ]
Tender For supply of ductable ac - ductable ac , itc of ductable ac , refrigerant piping , ms frame , 3x2.5 sq.mm pvc copper conductor , m s cable tray , pvc flaxible pipe , aluminium supply airgrills , gss sheet 24 gauge , fire retardent canvass
Tender For supply of cleaning or service of split type window type tower air conditioners of different capacities i.e. 1.5 ton or 2.0 ton in below mentioned offices of jda under jurisdiction of jda division 1 , replacement of damaged compressor for 1.5 ton window type air conditioner , replacement of damaged compressor for 2.0 ton window tower hot-n-cold type air conditioner , replacement of damaged compressor for 1.5 ton split type air conditioner , replacement of damaged compressor for 2.0 ton window tower hot cold type air conditioner , refilling of gas in 1.5 ton window type air conditioner , refilling of gas in 2.0 ton window type air conditioner , refilling of gas in 1.5 ton spilt type air conditioner , refilling of gas in 2.0 ton 2.0 ton split type air conditioner , replacement of damaged capacitor in 1.5 ton window type air conditioner , replacement of damaged capacitor in 2.0 ton window type air conditioner , replacement of damaged capacitor in 1.5 ton split type air conditioner , replacement of damaged capacitor in 2.0 ton split type air conditioner , replacement of damaged pcb in 1.5 ton window type air conditioner , replacement of damaged pcb in 2.0 ton window type air conditioner , replacement of damaged pcb in 1.5 ton split type air conditioner , replacement of damaged pcb in 2.0 ton split type air conditioner , replacement of damaged copper pipe , repair of stabilizer 3 or 4kva stabilizer , repair of stabilizer 5 or 6kva stabilizer , replacement of damaged or non repairable 3 or 4 kva copper wound stabilizer , replacement of damaged or non repairable 5 or kva copper wound stabilizer , replacement of damaged spn 63a , replacement of damaged spn 40a , replacement of damaged drain pipe , replacement of damaged wire 6.0 sq.mm , replacement of damaged front frame and grill of window type ac 1.5ton and 2.0 ton , replacement of damaged compressor of water cooler , replacement of damaged motor of water cooler , repair of thermostat of water cooler , repair of relay of water cooler , shifting of ac window split type tower type from one location to another , maintainence and attending complaint of ac and water cooler incl visit charges or minor repair without material , replacement of inner unit of 1.5 or 2.0 ton split type air conditioner , replacement of remote contol of window split and tower ac